Sizing a lantern against the room and the roof
A roof lantern gets sized twice: once against the room below, so it sits settled in the ceiling, and once against the roof it goes into, so the joists, the falls and the drainage still work around it.
Start with the room, because that is where you will judge it every day. A lantern skylight that fills the ceiling edge to edge looks like the roof has been left off. One that is too small reads as an afterthought, a glazed box perched on a flat roof with a narrow shaft below it. The proportion that tends to look right is an opening somewhere between a third and a half of the room's width, running along the room's longer side, with a clear border of flat ceiling all round. Treat that as a starting point for the drawing, not a formula. A tall ceiling can carry a bigger lantern; a low one, or a room with a steel beam over the doors, often wants a smaller, longer shape.
That flat border matters more than it first appears. Around 500 to 600mm of plain ceiling between the lantern lining and the walls gives the eye a frame to read the sky against, leaves room for downlights and pendant fixings, and keeps the lantern clear of the steel or lintel that carries the doors. Take the border away and the lining runs straight into the wall plaster, which makes the room feel lopsided when you stand in the doorway.
Take a typical single-storey rear extension off a Fletton brick terrace: about 3 metres deep and the full width of the house. The long axis runs across the plot, so the lantern runs across it too, parallel to the back wall of the house. On a wider extension in Hampton or Werrington, perhaps 4 by 5 metres, the lantern can be longer and a little wider, and the question moves from "how big" to "where exactly", which is the section further down. Our guide to sizing a roof lantern for your extension works through room shapes and ceiling heights in more detail.
Then the roof decides what is possible
Every lantern sits in a hole in the roof deck, and the hole cuts through joists. The joists that are cut have to be picked up by new trimmers, and the trimmers carry that load back to the joists either side. So the direction the joists run, their size and their span all shape the opening. An opening that runs with the joists cuts fewer of them than one that runs across them. A bigger opening, or one in a roof with shallow joists, may need doubled trimmers, a timber or steel beam, or an engineer's calculation before anyone picks up a saw.
The lantern also adds weight. A double-glazed lantern with a laminated inner pane is a heavy thing spread along a narrow kerb, and snow load has to be allowed for on top. On a new extension this is designed in from the start. On an existing flat roof it has to be checked, which is exactly what our answer on whether your flat roof can take the weight of a roof lantern covers.
Two more measurements catch people out. First, flat roofs are not flat: they fall towards a gutter or outlet, and guidance for flat roofs aims for a finished fall of at least 1:80, which means designing for about 1:40 to allow for deflection and building tolerance. The lantern itself has to sit level, so the kerb under it is built deeper on the low side than on the high side. Second, the size on a lantern's order is usually the outside of the kerb it sits on, not the hole you see from the kitchen. The kerb walls and lining take up some of that, so the clear opening from below is smaller than the headline size. When we draw your lantern we give both numbers, so nobody is surprised on the day.